1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback
OS758-LS-Series
-35 °C to 1600 °C Dual Laser Infrared Thermocouple Thermometer
- Wide Measurement Range: Infrared up to 1600°C (2912°F)
- Dual Laser Points for the Target Spot Size
- Narrow FOV, Distance to Spot Ratio of 60:1
- Hi/Low Temp Alarm
OS758-LS-Series
From
C$
916.18

Product Overview
- Accuracy ± 2 °C (± 3.6 °F)
- Accuracy Detail (T amb = 23 ± 3°C): T = -35 to 0°C: ± (2°C+0.05/°C) T = 0 to 1600: ± 2% of reading or 2°C (4°F) whichever is greater
- Applications Building and Maintenance, Industrial and Manufacturing, Laboratories and Scientific
- Battery life 14 hr
- Battery Size and Type Alkaline AA
- Display Monitoring Function Average, Differential, Hi Alarm, Lo Alarm, Lock, Max, Min, Real-time
- Display Note Color Backlit LCD
- Display Type LCD
- Emissivity, Max 1
- Emissivity, Min 0.1
- Emissivity Note 0.95 default adjustable 0.1 to 1 step 0.01
- Field of view 60:1
- Field of View Note 60:1 (90% energy covered)
- Form factor Pistol Grip
- Height 203 mm
- Laser Dual Laser
- Length 176 mm
- Memory Detailed 24 memories with temperature and emissivity, Support 8GB micro SD card
- Process Temperature, Min -35 °C
- Resolution 0.1°C
- Resolution Note 0.1°C/0.1°F at -83.2 to 999.9 (°C/°F), otherwise 1°C/1°F
- Response Time 1 sec
- Response Time Note 1 second (90% response)
- Spectral Response, Max 14 µm
- Temperature Sensor Type Thermocouple Type K
- Weight 401 g
- Weight Note 401 g (14.14 oz) including batteries (AA x 2 pcs)
- Width 58 mm
The high-performance, handheld OS758-LS dual infrared thermometer is a non-contact temperature measurement instrument. The OS758-LS offers a wide array of features including adjustable emissivity, color backlit LCD, 60:1 distance to spot, hi/ low temp alarm, max/min/avg/diff temperature monitoring and data storage. This meter is also designed with a microSD card slot (SD card included).
The OS758-LS offers a rugged design that is shatterproof at 1 m (3.3') with an ergonomic rubber boot handle. A Type K thermocouple input is included for contact measurements, often used to verify emissivity.
Specifications
Measurement Range: -35 to 1600°C (-31 to 2912°F)
Accuracy (T amb = 23 ± 3°C):
T = -35 to 0°C: ± (2°C+0.05/°C)
T = 0 to 1600: ± 2% of reading or 2°C (4°F) whichever is greater
Emissivity Range: 0.95 default adjustable 0.1 to 1 step 0.01
Resolution: 0.1°C/0.1°F at -83.2 to 999.9 (°C/°F), otherwise 1°C/1°F
Spectral Range: 8 to14 µm Response Time (90%): 1 sec
Distance to Spot: 60:1 (90% energy covered)
Modes: Real-time, max/min/avg/diff, lock, hi/low temp alarm
Internal Memory: Detailed 24 memories with temperature and emissivity
External Memory Type: Support 8G micro SD card
Battery Life: Typical 14 hours, minimum 10 hours continuous use (alkaline, with laser and backlight)
Dimensions: 203 H x 176 D x 58 W mm (8 x 6.9 x 2.3')
Weight: 401 g (14.14 oz) including batteries (AA x 2 pcs)
Read More
The OS758-LS offers a rugged design that is shatterproof at 1 m (3.3') with an ergonomic rubber boot handle. A Type K thermocouple input is included for contact measurements, often used to verify emissivity.
Specifications
Measurement Range: -35 to 1600°C (-31 to 2912°F)
Accuracy (T amb = 23 ± 3°C):
T = -35 to 0°C: ± (2°C+0.05/°C)
T = 0 to 1600: ± 2% of reading or 2°C (4°F) whichever is greater
Emissivity Range: 0.95 default adjustable 0.1 to 1 step 0.01
Resolution: 0.1°C/0.1°F at -83.2 to 999.9 (°C/°F), otherwise 1°C/1°F
Spectral Range: 8 to14 µm Response Time (90%): 1 sec
Distance to Spot: 60:1 (90% energy covered)
Modes: Real-time, max/min/avg/diff, lock, hi/low temp alarm
Internal Memory: Detailed 24 memories with temperature and emissivity
External Memory Type: Support 8G micro SD card
Battery Life: Typical 14 hours, minimum 10 hours continuous use (alkaline, with laser and backlight)
Dimensions: 203 H x 176 D x 58 W mm (8 x 6.9 x 2.3')
Weight: 401 g (14.14 oz) including batteries (AA x 2 pcs)